Print Page

Disposable Vitrectomy Lenses, Scleral Buckling Components for Retinal Detachment Surgery, and More

FCI Ophthalmics is a world leader in the development of disposable vitrectomy lenses, scleral buckling components for retinal detachment surgery, and a wide range of other ophthalmic surgical devices. FCI Ophthalmics performs extensive research and development to provide physicians with outstanding products that enhance the efficiency and effectiveness of retinal procedures.

To learn about disposable vitrectomy lenses, scleral buckling components for retinal detachment surgery, and other ophthalmic surgical devices, contact FCI Ophthalmics.

Disposable Vitrectomy Lenses

Disposable vitrectomy lenses from FCI Ophthalmics offer physicians a highly effective, single-use solution to precisely view the retinal surface during surgery. Planoconcave silicone and 30 degree prismatic lenses are offered.

S5-7010u
S5-7030u
Planoconcave Silicone Lens, Box of 5, sterile
30° Prismatic Silicone Lens, Box of 5, sterile

 

Back to Top

Scleral Buckling Components

Scleral buckling is the most frequently performed procedure for repairing retinal detachment. The following components help physicians effectively perform the surgery. Scleral buckling is most commonly used when the break is very large. It is also used if the tear is in one location and to seal breaks in one location.

SUB 100 Series Type

BAND (Type 40)
S5-1005u
Box of 5, sterile
BAND (Type 41)
S5-1015u
Box of 5, sterile
BAND (Type 42)
S5-1025u
Box of 5, sterile
STRIP (Type 20)
S5-1105u
Box of 5, sterile
STRIP (Type 31)
S5-1205u
Box of 5, sterile
STRIP (Type 32)
S5-1255u
Box of 5, sterile
TIRE 12 (Type 78G)
S5-1305u
Box of 5, sterile

200 Series Type

BAND (Type 240)
S5-2005u
Box of 5, sterile
STRIP (Type 219)
S5-2105u
Box of 5, sterile
STRIP (Type 220)
S5-2205u
Box of 5, sterile
STRIP (Type 225)
S5-2255u
Box of 5, sterile
ASYMMETRICAL TIRE 9 (Type 276)
S5-2295u
Box of 5, sterile
TIRE 9 (Type 277)
S5-2305u
Box of 5, sterile
BICONVEX TIRE 9 (Type 287)
S5-1255u
Box of 5, sterile
BICONVEX TIRE 12 (Type 289)
S5-2325u
Box of 5, sterile
TIRE 11 (Type 279)
S5-2335u
Box of 5, sterile
ASYMMETRICAL TIRE 12 (Type 280)
S5-2345u
Box of 5, sterile

Sleeves

FIXATION SLEEVE (Type 70) for S5-1005
S5-3005u
Box of 5, sterile
FIXATION SLEEVE (Type 270) for S5-2005
S5-3510u
Box of 5, sterile
FIXATION SLEEVE (Type 71) for S5-1015
S5-3515u
Box of 5, sterile
FIXATION SLEEVE (Type 72) for S5-1025
S5-3025u
Box of 5, sterile
WATZKE FORCEPS To fix sleeves onto bands
S5-3100u
Box of 1, non-sterile

500 Series Sponge Type

3 mm SPONGE (Type 503)
S5-6503u
Box of 5, sterile
4 mm SPONGE (Type 504)
S5-6504u
Box of 5, sterile
5 mm SPONGE (Type 505)
S5-6505u
Box of 5, sterile
5 mm GROOVED SPONGE (Type 505 G)
S5-6520u
Box of 5, sterile
3 x 5 SPONGE (TYPE 506)
S5-6535u
Box of 5, sterile
3 x 5 GROOVED SPONGE (Type 506 G)
S5-6540u
Box of 5, sterile
5.5 x 7.5 SPONGE (Type 507)
S5-6557u
Box of 5, sterile
5.5 x 7.5 GROOVED SPONGE (Type 507 G)
S5-6560u
Box of 5, sterile
7.5 x 3.5 GROOVED SPONGE (TYPE 509 G)
S5-6570u
Box of 5, sterile
2.5 x 5 HALF-SPONGE (Type 510)
S5-6550u
Box of 5, sterile
2.5 x 7.5 HALF-SPONGE (Type 511)
S5-6575u
Box of 5, sterile
3.25 x 7.0 SPONGE (Type 907)
S5-6585u
Box of 5, sterile

 

Back to Top

About Scleral Buckling

Scleral buckling is an effective means of closing breaks, bringing two layers of the retina back together, and ridding the eye of fluid under the retina. During the scleral buckling procedure, the buckle is sewn to the outer layer of the eye, keeping it securely in place. The buckle is usually permanently attached. This pushes — or "buckles" — the sclera toward the middle of the eye, which relieves the traction on the retina and allows the retinal tear to settle and reheal against the wall of the eye.

 

Back to Top

Downloads

Coming Soon

 

Back to Top

Ophthalmic surgical devices from FCI include disposable vitrectomy lenses, scleral buckling components for retinal detachment surgery, as well as a full range of cataract surgery devices, orbital implants, lacrimal stents and tubes, lid repair products, and aesthetic sutures. To learn more about our many surgical devices, contact FCI Ophthalmics.

FCI Ophthalmics
P.O. Box 465
Marshfield Hills, MA
02051

Tel: 866-595-4947
Tel: 781-826-9060
Fax: 781-826-9062

For the latest information regarding disposable vitrectomy lenses, scleral buckling components for retina detachment surgery, and our many other products, contact FCI Ophthalmics.