Intravitreal Injection Assistants, Disposable Vitrectomy Lenses, Scleral Buckling Components for Retinal Detachment Surgery, and More

FCI Ophthalmics is a world leader in the development of intravitreal injection assistants, disposable vitrectomy lenses, scleral buckling components for retinal detachment surgery, and a wide range of other ophthalmic surgical devices. FCI Ophthalmics performs extensive research and development to provide physicians with outstanding products that enhance the efficiency and effectiveness of retinal procedures.

To learn about disposable vitrectomy lenses, scleral buckling components for retinal detachment surgery, and other ophthalmic surgical devices, contact FCI Ophthalmics.

 

 

InVitria® - Intravitreal Injection Assistant

The InVitria injection assistant, designed by Arnaldo Goncalves, M.D. of the Netherlands, is a disposable device that simplifies intravitreal injections by making the procedure faster and more predictable. The unique design is equipped with a guide tube which is specially oriented to ensure a fixed injection angle, position, and depth.  Use of the InVitria ensures a predictable and fast procedure without the need for instruments like a speculum, calibrator or pressure plate.

After preparing the patient for the procedure, the InVitria is carefully placed on the patient's eye using the positioning line in the center of the device.  By gently pushing down and turning the device, the eye becomes fixated and the patient feels an anesthetic effect due to the pressure.  With the patient unable to move the eye or see the needle, the physician can safely insert the injection into the eye using the guide tube of the InVitria device, ensuring the proper angle, depth and distance from the limbus.  The point of injection is always at 3.5mm from the orientation line.  Turning the InVitria after removing the needle gives a stepped injection hole due to the displacement of the conjunctiva.

Because of it's simple use, the Goncalves InVitria injection assistant is very user-friendly, patient-friendly and budget-friendly.

MW-200      Intravitreal Injection Assistant, box of 25, sterile

                      

  • Designed by Arnaldo Gonçalves, MD from Holland
  • Material: Makrolon 2458
  • Fixed 28° angle
  • Fixed 5.60mm depth
  • Fixed 3.5mm distance from the limbusSterile transluscent plastic
  • Position line for orientating on the limbus
  • Ergonomic grip
  • Flange for optimal positioning and control

 

 


 

 

 

 

 

 

 

 

Disposable Vitrectomy Lenses

Disposable vitrectomy lenses from FCI Ophthalmics offer physicians a highly effective, single-use solution to precisely view the retinal surface during surgery. Planoconcave silicone and 30 degree prismatic lenses are offered.

S5-7010u     Planoconcave Silicone Lens, Box of 5, sterile
S5-7030u     30° Prismatic Silicone Lens, Box of 5, sterile

 

 

 

Scleral Buckling Components

Scleral buckling is the most frequently performed procedure for repairing retinal detachment. The following components help physicians effectively perform the surgery. Scleral buckling is most commonly used when the break is very large. It is also used if the tear is in one location and to seal breaks in one location.

SUB 100 Series Type

BAND (Type 40)
S5-1005u
Box of 5, sterile
BAND (Type 41)
S5-1015u
Box of 5, sterile
BAND (Type 42)
S5-1025u
Box of 5, sterile
STRIP (Type 20)
S5-1105u
Box of 5, sterile
STRIP (Type 31)
S5-1205u
Box of 5, sterile
STRIP (Type 32)
S5-1255u
Box of 5, sterile
TIRE 12 (Type 78G)
S5-1305u
Box of 5, sterile

200 Series Type

BAND (Type 240)
S5-2005u
Box of 5, sterile
STRIP (Type 219)
S5-2105u
Box of 5, sterile
STRIP (Type 220)
S5-2205u
Box of 5, sterile
STRIP (Type 225)
S5-2255u
Box of 5, sterile
ASYMMETRICAL TIRE 9 (Type 276)
S5-2295u
Box of 5, sterile
TIRE 9 (Type 277)
S5-2305u
Box of 5, sterile
BICONVEX TIRE 9 (Type 287)
S5-1255u
Box of 5, sterile
BICONVEX TIRE 12 (Type 289)
S5-2325u
Box of 5, sterile
TIRE 11 (Type 279)
S5-2335u
Box of 5, sterile
ASYMMETRICAL TIRE 12 (Type 280)
S5-2345u
Box of 5, sterile

Sleeves

FIXATION SLEEVE (Type 70) for S5-1005
S5-3005u
Box of 5, sterile
FIXATION SLEEVE (Type 270) for S5-2005
S5-3510u
Box of 5, sterile
FIXATION SLEEVE (Type 71) for S5-1015
S5-3515u
Box of 5, sterile
FIXATION SLEEVE (Type 72) for S5-1025
S5-3025u
Box of 5, sterile
WATZKE FORCEPS To fix sleeves onto bands
S5-3100u
Box of 1, non-sterile

500 Series Sponge Type

3 mm SPONGE (Type 503)
S5-6503u
Box of 5, sterile
4 mm SPONGE (Type 504)
S5-6504u
Box of 5, sterile
5 mm SPONGE (Type 505)
S5-6505u
Box of 5, sterile
5 mm GROOVED SPONGE (Type 505 G)
S5-6520u
Box of 5, sterile
3 x 5 SPONGE (TYPE 506)
S5-6535u
Box of 5, sterile
3 x 5 GROOVED SPONGE (Type 506 G)
S5-6540u
Box of 5, sterile
5.5 x 7.5 SPONGE (Type 507)
S5-6557u
Box of 5, sterile
5.5 x 7.5 GROOVED SPONGE (Type 507 G)
S5-6560u
Box of 5, sterile
7.5 x 3.5 GROOVED SPONGE (TYPE 509 G)
S5-6570u
Box of 5, sterile
2.5 x 5 HALF-SPONGE (Type 510)
S5-6550u
Box of 5, sterile
2.5 x 7.5 HALF-SPONGE (Type 511)
S5-6575u
Box of 5, sterile
3.25 x 7.0 SPONGE (Type 907)
S5-6585u
Box of 5, sterile

 

Back to Top

 

About Scleral Buckling

Scleral buckling is an effective means of closing breaks, bringing two layers of the retina back together, and ridding the eye of fluid under the retina. During the scleral buckling procedure, the buckle is sewn to the outer layer of the eye, keeping it securely in place. The buckle is usually permanently attached. This pushes — or "buckles" — the sclera toward the middle of the eye, which relieves the traction on the retina and allows the retinal tear to settle and reheal against the wall of the eye.

 